September 1, 1992Proceedings of the National Academy of Sciences438 citationsOpen Access

Electrical method for detection of endothelial cell shape change in real time: assessment of endothelial barrier function.

View Full Paper
CTChinnaswamy TiruppathìAMAsrar B. MalikPVPeter J. Del Vecchio

Key Points

Key points are not available for this paper at this time.

Abstract

We have developed an electrical method to study endothelial cell shape changes in real time in order to examine the mechanisms of alterations in the endothelial barrier function. Endothelial shape changes were quantified by using a monolayer of endothelial cells grown on a small (10(-3) cm2) evaporated gold electrode and measuring the changes in electrical impedance. Bovine pulmonary microvessel endothelial cells and bovine pulmonary artery endothelial cells were used to study the effects of alpha-thrombin on cell-shape dynamics by the impedance measurement. alpha-Thrombin produced a dose-dependent decrease in impedance that occurred within 0.5 min in both cell types, indicative of retraction of endothelial cells and widening of interendothelial junctions because of "rounding up" of the cells. The alpha-thrombin-induced decrease in impedance persisted for approximately 2 hr, after which the value recovered to basal levels. Pretreatment of endothelial cells with the protein kinase C inhibitor, calphostin C, or with 8-bromoadenosine 3',5'-cyclic monophosphate prevented the decreased impedance, suggesting that the endothelial cell change is modulated by activation of second-messenger pathways. The alpha-thrombin-induced decrease in impedance was in agreement with the previously observed increases in transendothelial albumin permeability and evidence of formation of intercellular gaps after alpha-thrombin challenge. The impedance measurement may be a valuable in vitro method for the assessment of mechanisms of decreased endothelial barrier function occurring with inflammatory mediators. Since the rapidly occurring changes in endothelial cell shape in response to mediators such as thrombin are mediated activation of second-messenger pathways, the ability to monitor endothelial cell dynamics in real time may provide insights into the signal-transduction events mediating the increased endothelial permeability.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tiruppathì et al. (1992) studied this question.

synapsesocial.com/papers/69deef865e217d93a555909ahttps://doi.org/10.1073/pnas.89.17.7919
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Electric measurements can be used to monitor the attachment and spreading of cells in tissue culture.1991 · 131 citations
  2. 2Monitoring fibroblast behavior in tissue culture with an applied electric field.1984 · 606 citations
  3. 3Tumor promoter-induced changes in the permeability of epithelial cell tight junctions1981 · 184 citations
  4. 4Permeability of human endothelial monolayers: effect of vasoactive agonists and cAMP1989 · 131 citations
  5. 5Modulation of solute permeability in microvascular endothelium.1986 · 82 citations