April 15, 2026Infection Prevention in Practice0 citationsOpen Access

Surface Microbiological Surveillance in a Crowded Emergency Department: Interplay of Environmental Pressure, Construction, and Disinfection Efficacy

View Full Paper
KZKhédija ZaoucheTunis El Manar UniversityLJL. JmalTunis El Manar UniversityAAAmeni AMDOUNITunis El Manar University

Key Points

  • The aim is to understand how environmental and organizational stressors affect surface contamination in emergency departments.
  • Conducted monthly microbiological surface surveillance for 11 months.
  • Used contact plates to sample high-touch surfaces and walls.
  • Documented ED occupancy and construction activities alongside sampling.
  • Bacillus spp. contamination increased during construction phases.
  • Elevated Staphylococcus aureus levels were linked to high occupancy rates.
  • No indicator organisms were found during periods of low activity and no construction.

Abstract

Environmental surface contamination in Emergency Departments (EDs) is a recognized contributor to pathogen transmission. However, its relationship with organizational and environmental stressors remains insufficiently characterized. Between January and November 2025, monthly microbiological surface surveillance was conducted in a tertiary ED with approximately 70,000 annual visits. Standardized sampling using contact plates (25 cm 2 ) targeted predefined sites, including high-touch surfaces, equipment, and walls. Indicator organisms included Staphylococcus aureus, Bacillus spp., and Enterobacteriaceae. Environmental factors, including ED occupancy and construction activities, were documented. Cleaning protocols remained unchanged throughout the study. Bacillus spp. contamination was predominantly observed during construction phases, consistent with environmental dust dispersion. Elevated S. aureus contamination coincided with periods of severe overcrowding (up to 98% occupancy). During a control period with low activity and no construction, no indicator organisms were detected on sampled surfaces. Enterobacteriaceae were only sporadically identified. Surface contamination patterns were strongly associated with environmental and organizational stressors rather than disinfection failure. Microbiological surveillance may serve as an operational indicator of system strain in emergency care settings.