A Grid-Connected Solar PV/Wind Turbine Based Hybrid Energy System Using ANFIS Controller for Hybrid Series Active Power Filter to Improve the Power Quality

PCPazhanimuthu CholamuthuIBI. BaranilingesanSPSuresh Kalichikadu Paramasivam

Key Points

Key points are not available for this paper at this time.

Abstract

The current needs of more nonlinear loads and the frequent usage of single-phase loads in three-phase system drastically create power quality issues in the grid-connected system. As a consequence, it creates an undesirable power quality issue (PQI) in the form of a change in the nature of voltage and current magnitude and waveforms in the power system. The voltage-related PQI leads to a huge disturbance in the system when compared with the current-related PQI. The hybrid series active power filter provides grids with the required voltage in series and suppresses the voltage-related harmonics caused by grid-connected nonlinear loads. The present work deals with an adaptive neurofuzzy inference system controller for the generation of a reference voltage signal that uses a reduced active filter rating. The simulation study was done in the MATLAB 2020b/Simulink environment and the experimental effectiveness of the proposed ANFIS controller was compared with that of a conventional controller. In the grid-connected system, this system prevents voltage quality problems such as voltage sag, flickering, voltage swell, neutral currents, and reactive power. The renewable energy sources interfaced into the DC-link minimize short and long voltage challenges so that they improve the overall performance of the system. In accordance with IEEE standard 519-1992, a prototype model was proved to demonstrate that the power delivery system works effectively under different conditions and reduces the total harmonic distortion by approximately 30%, which is less than the 5% acceptable limit.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Cholamuthu et al. (2022) studied this question.

synapsesocial.com/papers/69dff618af3798be7f860348https://doi.org/10.1155/2022/9374638
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Design of Passive Power Filter for Hybrid Series Active Power Filter using Estimation, Detection and Classification Method2016 · 13 citations
  2. 2A novel control method for series hybrid active power filter working under unbalanced supply conditions2014 · 25 citations
  3. 3Experimental Investigation on a Hybrid Series Active Power Compensator to Improve Power Quality of Typical Households2016 · 106 citations
  4. 4A Novel Series Power Quality Controller With Reduced Passive Power Filter2016 · 59 citations
  5. 5Analysis, Design, Modeling, and Control of an Interleaved-Boost Full-Bridge Three-Port Converter for Hybrid Renewable Energy Systems2016 · 191 citations