April 16, 2026

All-fiber multifunction differential absorption CO

View Full Paper
Ask AI
Bookmark
Share

Authors

CWChong WangXXXianghui XueYWYu Wang

Discussion

Loading...

Member takes

Overview

Multifunction lidar detects CO2 concentration and wind field, highlighting advanced detection capabilities.

Key Points

  • To develop a multifunctional differential absorption lidar (DIAL) for accurate CO2 and wind detection.
  • Developed using single-photon and coherent detection techniques.
  • Compared DIAL CO2 concentration with VAISALA-GMP343 for accuracy assessment.
  • Conducted scanning detection experiments in Chaohu Lake, Hefei.
  • DIAL achieved less than 5 ppm deviation in CO2 concentration measurements compared to VAISALA-GMP343.
  • Successfully measured CO2 concentration and wind field using both detection methods.
  • Single-photon detection provided 3-km range for CO2 and aerosol backscattering signals; coherent detection improved blind zone to 360 m.

Cite This Study

Wang et al. (2026) studied this question.

synapsesocial.com/papers/69e07c972f7e8953b7cbdbeehttps://doi.org/10.1051/epjconf/202636214002/pdf