Comparative analysis examines polymerization effectiveness in resin composites, suggesting optimal curing conditions.
This article aims to compare the polymerization effectiveness of two curing modes of a polywave LED unit in four conventional resin composites at a 2-mm increment thickness, using bottom/top microhardness ratios as the evaluation method. Cylindrical specimens (5 mm in diameter and 2 mm in thickness; n = 20 per material) were prepared from four composites: Charisma Classic (CC), Filtek Ultimate (FU), G-aenial Posterior (GP), and Clearfil Photo Posterior (CP). According to the curing protocol, each material was assigned to two subgroups (n = 10 per subgroup), resulting in eight groups and a total of 80 specimens using a Valo PolyWave LED: standard mode (Mode 1: ≈ 1,200 mW/cm2, 20 seconds and high-power mode (Mode 2; ≈3,200 mW/cm2, 12 seconds. Light output and spectral distribution were verified with a radiometer and spectrometer. After storing the specimens for 24 hours in water at 37 °C, Vickers microhardness was measured on the top and bottom surfaces. Then, the bottom:top hardness ratios were calculated. A ratio ≥0.80 was considered indicative of clinically acceptable curing. Data were analyzed using two-way ANOVA (curing mode × composite type), with additional post hoc comparisons performed where appropriate; categorical outcomes were evaluated using Fisher's exact test (α = 0.05). No significant difference was found in bottom:top hardness ratios between Mode 1 and Mode 2 within FU, GP, or CP (p > 0.05). However, CC showed a significant reduction with Mode 2 (p = 0.022). The mean ratios for Mode 1 were ≥0.80 for CC, FU, and CP (ranging from 0.84 to 0.85), and were slightly below 0.80 for GP (0.79). In contrast, all materials in Mode 2 exhibited mean ratios below 0.80 (ranging from 0.75 to 0.78). The proportion of specimens with ratios ≥0.80 in Mode 1 ranged from 30% (GP) to 90% (FU); however, it was lower in Mode 2 for all materials. CP exhibited the highest hardness values and GP the lowest, irrespective of curing mode. Despite delivering higher total radiant exposure, the high-power/short-time mode of the PolyWave LED did not improve deep polymerization of 2-mm increments; often, it compromised it. For conventional resin composites, standard power with longer exposure is a more reliable method of achieving clinically acceptable curing at a 2-mm depth. High-power modes should only be used for thin surface layers or repair procedures.
No takes yet. Share an insight, caveat, or question.
Hatice Sümeyye Kiliç (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: