April 18, 2026Energy Conversion and Management2 citationsOpen Access

PEM Water Electrolyzer Robust Control Under Renewable Energy Source Intermittency

View Full Paper
MZMeziane Ait ZianeMZMichel ZasadzinskiCentre National de la Recherche ScientifiqueHRHugues RafaralahyCentre National de la Recherche Scientifique

Key Points

  • This research aims to develop robust control strategies for a proton exchange membrane water electrolyzer to manage hydrogen production effectively during variable renewable energy conditions.
  • Designed a model using output error identification method.
  • Developed a state-space model of the electrolyzer and converter by averaging method.
  • Implemented robust control strategy based on normalized coprime factorizations.
  • Reduced the full-order controller via frequency-weighted closed-loop sensitivity functions.
  • Conducted experimental validation to assess controller performance.
  • Proposed several methods for identifying the electrolyzer behavior.
  • Controller demonstrated robustness against variations from renewable energy sources.
  • Reduced-order controller performed equally to full-order controller in closed-loop testing.
  • Experimental tests confirmed control effectiveness under changing environmental conditions.

Abstract

This paper investigates the design and experimental validation of robust control for a proton exchange membrane water electrolyzer integrated with a stacked interleaved buck converter, aimed at regulating hydrogen production from renewable energy source. A model of the electrolyzer is obtained using the output error identification method. A State-space model of the electrolyzer coupled with the converter is therefore determined using the averaging method. To address variations in operating conditions during hydrogen production under renewable energy source intermittency, a robust control strategy based on normalized coprime factorizations is implemented. The obtained the full-order controller is reduced using a method that incorporates closed-loop behavior into the truncation process via frequency-weighted closed-loop sensitivity functions. Experimental validation demonstrates the controller’s efficacy in adapting to changes in set-points and environmental conditions, underlining its theoretical robustness against renewable energy source intermittency. • Several PEMWE identification methods are proposed and discussed. • Designed controller ensures robustness against RES variations. • Reduced-order controller achieves same performance as full-order one in closed-loop. • Experimental validation of PEMWE control under RES intermittency.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ziane et al. (2026) studied this question.