Dozens of monoclonal antibodies (mAbs) have been approved for clinical use, and hundreds more are under development. To support these developments and facilitate a personalized medicine approach, PET imaging and quantification of mAbs, after chelation with desferrioxamine B (DFO) and radiolabeling with ⁸⁹Zr, has become attractive. Also, the use of ⁸⁹Zr-mAbs in preclinical and clinical studies is expanding rapidly. Despite these rapid developments, ⁸⁹Zr radiolabeling is still performed manually. Therefore, we aimed to develop a simple, fully automated, good-manufacturing-practice (GMP)-compliant production procedure for the ⁸⁹Zr labeling of mAbs. Such procedures should increase the robustness and capacity of ⁸⁹Zr-mAb production while minimizing the radiation dose to the operator. Here, the procedures for fully automated ⁸⁹Zr-mAb production are described and applied to produce batches of ⁸⁹Zr-DFO-N-suc-cetuximab and ⁸⁹Zr-DFO-N-suc-rituximab suitable for clinical use. Both products had to meet the GMP-compliant quality standards with respect to yield, radiochemical purity, protein integrity, antigen binding, sterility, and endotoxin levels. Methods: Automated ⁸⁹Zr labeling of mAbs was developed on a Scintomics GRP 2V module and comprised the following steps: reagent transfer to the ⁸⁹Zr-containing reaction vial, mixing of the reagents followed by a 60-min reaction at room temperature to obtain optimal radiolabeling yields, and product purification using a PD-10 desalting column. Results: Radiochemical yields of ⁸⁹Zr-DFO-N-suc-cetuximab and ⁸⁹Zr-DFO-N-suc-rituximab were all more than 90% according to instant thin-layer chromatography. Isolated yields were 74.6% ± 2.0% and 62.6% ± 3.0% for ⁸⁹Zr-DFO-N-suc-cetuximab and ⁸⁹Zr-DFO-N-suc-rituximab, respectively, which are similar to isolated yields obtained using GMP protocols for manual ⁸⁹Zr labeling of mAbs. To meet the GMP-compliant quality standards, only the radiochemically pure fractions were collected from PD-10, resulting in a lower isolated yield than the radiochemical yield according to instant thin-layer chromatography. The radiochemical purity and protein integrity were more than 95% for both products, and the antigen binding was 95.6% ± 0.6% and 87.1% ± 2.2% for ⁸⁹Zr-DFO-N-suc-cetuximab and ⁸⁹Zr-DFO-N-suc-rituximab, respectively. The products were sterile, and the endotoxin levels were within acceptable limits, allowing future clinical production using this procedure. Conclusion: Procedures for fully automated GMP-compliant production of ⁸⁹Zr-mAbs were developed on a commercially available synthesis module, which also allows the GMP production of other radiolabeled mAbs.
No takes yet. Share an insight, caveat, or question.
Poot et al. (2018) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: