Corona discharge at the tip of buildings in a thunderstorm environment is an important factor causing changes in the near-ground electric field, but the influence of a quadratic growth law and quantitative research on the parameters is still rare. Therefore, based on the three-dimensional corona discharge model, this paper studies the influence of positive and negative symmetrical triangular wave electric fields with different amplitudes on the corona discharge of an independent lightning rod. Studies have shown that the corona current is synchronized with the peak of the background electric field. Studies have shown that the corona current is synchronized with the peak of the background electric field. When the polarity of the electric field changes from positive to negative, the positive charge accumulated in the positive half-cycle promotes the subsequent negative corona, so the negative corona starts in advance when the polarity reverses. Compared with unipolar discharge, the amplitude of the negative current and the number of negative charges have significantly improved. However, due to the counteraction of neutralization between positive and negative charges, the total corona charge is at a low level, which shows a net negative polarity result. The corona current and the amount of charge increase nonlinearly with an increase in the background electric field amplitude. Under the symmetrical triangular wave electric field, the quantitative fitting relationship between the peak value of the negative corona current in the second half-cycle and the amount of charge is established for the 5 m high independent lightning rod, which is I− = −0.0532 − 0.153 E − 0.0682 E2, Q− = −3.18 × 10−3 + 7.762 × 10−4E − 4.671 × 10−5 E2, respectively. The increase in the background electric field amplitude will aggravate the disturbance of the corona discharge to the near-surface electric field. When the direction of the electric field has reverted to zero, the existence of the space charge will lead to a significant change in the strength and polarity of the ground electric field. When the thunderstorm background electric field changes from positive to negative, the corona effect reverses the polarity of the ground electric field in advance, and the larger the peak value of the background electric field, the larger the advance. The corona interference mechanism revealed by this study can provide an important reference for correcting the electric field monitoring data and improving the accuracy of lightning warnings.
Zhang et al. (2026) studied this question.