Key result
The 'Ermenonville' classification for coronary angioscopy showed intra-observer kappa values of 0.51-0.67 and very low inter-observer kappa values of 0.13-0.29.
Why the study?
What is the intra- and inter-observer agreement of the 'Ermenonville' classification system for coronary angioscopy?
Observational
Yes
What is the intra- and inter-observer agreement of the 'Ermenonville' classification system for coronary angioscopy?
The 'Ermenonville' classification for coronary angioscopy has poor inter-observer agreement, highlighting the need for core laboratories in multicenter studies.
Answers are grounded in this paper and cite their sources.
Caution needed for clinical use of Ermenonville classification; leaves open research applications pending core laboratory standardization.
A European coronary angioscopy working group has been established to create and evaluate a classification system for angioscopic observation. The 'Ermenonville' classification features items, graded in 3-5 categories, such as lumen diameter, shape of narrowing, colours of surface, atheroma, dissection, thrombus, etc. Inter- and intra-observer agreement on the interpretation of angioscopic images, using this classification system, was studied within the working group. Kappa values for chance-corrected intra-observer agreement of the diagnostic items were 0.51-0.67. The mean kappa values for inter-observer agreement were very low at 0.13-0.29. The important items, such as red thrombus and dissection were studied after recoding as either present or absent. These items proved to have a good intra-observer agreement, and an acceptable inter-observer agreement after recoding. Other angioscopic diagnoses should be made with caution. Multicentre angioscopy studies should make use of an angioscopy core laboratory. A set of definitions for coronary angioscopy is proposed, and this working group will re-evaluate observer agreements using these definitions.
No takes yet. Share an insight, caveat, or question.
Heijer et al. (1994) conducted an observational in Coronary angioscopy observations. 'Ermenonville' classification system was evaluated on Inter- and intra-observer agreement (Kappa values) (Kappa 0.51-0.67 (intra-observer); 0.13-0.29 (inter-observer)). The 'Ermenonville' classification for coronary angioscopy showed intra-observer kappa values of 0.51-0.67 and very low inter-observer kappa values of 0.13-0.29.
Synapse has enriched 10 related papers. Consider them for comparative context: