Answers are grounded in this paper and cite their sources.
Demonstrates effective beam steering in ultrasonic inspection using FPGA technology, highlighting its potential for NDT applications.
This paper presents the design and implementation of a compact FPGA-based (Field-Programmable Gate Array) controlled ultrasonic transducer system. Our aim was to achieve ultrasound beam steering using three elementary ultrasonic transducers. The transducers generated a steerable beam through ultrasound interference, which was controlled by adjusting the phase differences between them. The system’s performance was demonstrated using a radar-style beamforming plot. Using elementary transmitters with an initial aperture angle of 50°-130°, an effective aperture angle of 74°-101° was achieved. The core of the device was implemented on a ZCU102 development panel, which had a considerable impact on the following development phase. Our proposed approach offers a compact and cost-effective solution for Non-Destructive Testing (NDT) systems; its applicability was demonstrated on a wood inspection example. Finally, potential directions for further development toward a fully functional device are discussed.
No takes yet. Share an insight, caveat, or question.
Varga et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: