Answers are grounded in this paper and cite their sources.
Demonstrates real-time monitoring of sweat lactate in athletes, highlighting its potential for personalized health tracking.
Non-invasive, real-time monitoring of lactate in sweat is critical for personalized health tracking and sports performance optimization. However, conventional enzyme-based lactate sensors suffer from limited stability and high cost, while many reported nanozyme systems exhibit optimal activity only under alkaline conditions, limiting their applicability in physiological environments. In this report, we develop a wearable integrated nanozyme-based electrochemical sensor for sweat lactate monitoring. The sensor comprises cobalt oxide (Co 3 O 4 ) and cobalt phosphate (Co 3 (PO 4 ) 2 ) nanoflakes on a screen-printed carbon electrode (SPCE), combined with a microfluidic unit for sweat collection and transport. Co 3 O 4 nanoflakes were electrodeposited and electrochemically activated to form a Co 3 O 4 /Co 3 (PO 4 ) 2 /SPCE platform for lactate detection. The structural morphologies, surface composition and chemical states, and crystalline information of the modified electrodes were analyzed using various analytical techniques, such as scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and transmission electron microscopy. The Co 3 O 4 /Co 3 (PO 4 ) 2 /SPCE exhibited robust electrocatalytic activity for lactate detection at neutral pH, yielding a dynamic range of 1 - 80 mM with a sensitivity of 8.3 μA mM -1 cm -2 and a limit of detection of 0.3 mM. The developed sensor offers good selectivity against common electroactive sweat components (ascorbic acid, uric acid, and glucose). The microfluidic integrated sensor was tested dynamically with different concentrations of lactate, yielding a sensitivity of 5.2 μA mM -1 cm -2 . The device was validated by on-body sweat lactate monitoring during cycling, showing excellent accuracy (>91%) versus a colorimetric reference test. The integrated sensor enables real-time sweat lactate analysis for sports monitoring and personalized health tracking. • Wearable nanozyme-based electrochemical sensor for real-time sweat lactate monitoring • The Co 3 O 4 /Co 3 (PO 4 ) 2 nanoflakes, successfully electrodeposited on a Screen-printed carbon electrode, exhibit strong electrocatalytic activity • Wide detection range (1–80 mM) and low detection limit (0.3 mM) at neutral pH • Integrated microfluidic patch for sweat collection and dynamic detection • Successful on-body validation with >91% accuracy during vigorous exercise
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: