PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 29, 2026Diagnostics0 citationsOpen Access

Diagnostic Performance of Saline Infusion Sonography with Color Doppler Flow (SIS-CF) for Assessing Tubal Patency: A Prospective Cohort Study

View Full Paper
PBPantana BangsomboonChiang Mai UniversityWLWorashorn LattiwongsakornChiang Mai UniversityTPTawiwan PanthasriChiang Mai University

Key Points

  • This study investigates the effectiveness of saline infusion sonography with color Doppler flow (SIS-CF) in assessing fallopian tube patency compared to laparoscopic chromopertubation.
  • Prospective diagnostic accuracy study conducted at Chiang Mai University Hospital from January to November 2025.
  • Participants underwent SIS-CF followed by laparoscopic chromopertubation in the same session.
  • Primary outcomes included diagnostic indices for tubal patency and procedural duration.
  • SIS-CF showed sensitivity of 89.4% (95% CI 78.1–95.9) and specificity of 95.5% (95% CI 77.2–99.9).
  • Positive predictive value was 98.3% and negative predictive value was 75.0%.
  • Overall accuracy of SIS-CF was 90.9% (95% CI 82.9–95.8).

Abstract

Background/Objectives: Accurate evaluation of fallopian tube patency is an essential step in infertility assessment. This study investigated the diagnostic capability of saline infusion sonography combined with color Doppler flow (SIS-CF), using laparoscopic chromopertubation as the comparator method. Methods: A prospective diagnostic accuracy study was conducted between January and November 2025 at the Infertility Unit, Chiang Mai University Hospital, Thailand. Women requiring laparoscopic assessment for infertility evaluation or preconception investigation were consecutively enrolled. Each participant underwent SIS-CF immediately before laparoscopic chromopertubation within the same operative session. Primary outcomes included diagnostic indices for tubal patency. Secondary outcomes included procedural duration and perioperative safety. Results: Forty-four women (88 fallopian tubes) were included. SIS-CF demonstrated sensitivity of 89.4% (95% CI 78.1–95.9) and specificity of 95.5% (95% CI 77.2–99.9). Positive and negative predictive values were 98.3% and 75.0%, respectively. Likelihood ratios were 19.65 (positive) and 0.11 (negative), with overall accuracy of 90.9% (95% CI 82.9–95.8). Median procedure duration was 5.7 min for SIS-CF and 3.0 min for laparoscopic chromopertubation. No adverse events were recorded. Conclusions: SIS-CF demonstrated favorable diagnostic characteristics for evaluation of tubal patency. The technique provided functional information regarding tubal status while maintaining a minimally invasive profile. Further investigation is warranted to determine its role within routine infertility workups.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bangsomboon et al. (2026) studied this question.

synapsesocial.com/papers/69f19f9cedf4b46824806554https://doi.org/10.3390/diagnostics16091287
Ask AI
Helpful
Bookmark
Share
View Full Paper