Key result
LQT2 is associated with worse electrical and mechanical dispersion than LQT1, including longer rest QTc.
Why the study?
Do electrical and mechanical parameters differ between patients with LQT1 and LQT2?
Observational (n=87)
Do electrical and mechanical parameters differ between patients with LQT1 and LQT2?
p-value: p=0.007
LQT2 patients exhibit more pronounced electromechanical abnormalities, including prolonged repolarization and contraction duration, compared to LQT1 patients.
Should not yet inform LQT2 risk stratification or diagnosis; leaves open radial CD as a hypothesis-generating mechanical marker.
Background: Congenital long QT syndrome (LQTS) is a rare cardiac disorder caused by repolarization abnormalities in the myocardium that predisposes to ventricular arrhythmias and sudden cardiac death. Potassium channel-mediated LQT1 and LQT2 are the most common types of channelopathy. Recently, LQTS has been acknowledged as an electromechanical disease. Methods: A total of 87 genotyped LQT1/LQT2 patients underwent cardiac evaluation. A comparison between LQT1 and LQT2 electrical and mechanical parameters was performed. Results: LQT2 patients had worse electrical parameters at rest: a longer QTc interval (p = 0.007), a longer Tpe in lead V2 (p = 0.028) and in lead V5 (p < 0.001), and a higher Tpe/QT ratio in lead V2 (p = 0.011) and in lead V5 (p = 0.005). Tpe and Tpe/QT remained significantly higher in the LQT2 group after brisk standing. Tpe was longer in LQT2 patients compared with LQT1 patients during peak exercise (p = 0.007) and almost all recovery periods in lead V2 during EST. The mid-cavity myocardium mean radial contraction duration (CD) was longer in LQT2 patients (p = 0.02). LQT2 patients had a longer mean radial CD in mid-septal (p = 0.015), mid-inferior (p = 0.034), and mid-posterior (p = 0.044) segments. Conclusions: Potassium channel-mediated LQTS has different effects on cardiac electromechanics with a more pronounced impact on LQT2 patients. Tpe was more prominent in the LQT2 cohort, not only at rest and brisk standing but also during EST exercise and at recovery phases. The altered mean radial CD in the mid-cavity myocardium was also specific for LQT2 patients.
No takes yet. Share an insight, caveat, or question.
Bileišienė et al. (2025) conducted an observational in Congenital long QT syndrome (LQTS) (n=87). LQT2 genotype vs. LQT1 genotype was evaluated on QTc interval at rest (p=0.007). LQT2 patients exhibited worse electrical and mechanical parameters compared with LQT1 patients, including a longer QTc interval at rest (p=0.007) and longer mean radial contraction duration (p=0.02).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: