Prospective cohort shows a new suction system enhances skin adherence in microtia patients, indicating a cost-effective solution.
In autologous microtia reconstruction, achieving optimal skin adherence to the cartilage framework is critical for aesthetic success. This study validates a novel, low-cost closed suction system assembled from a 20 mL syringe, a 5 mL syringe barrel acting as a rigid internal lock, and a fenestrated butterfly cannula. In a prospective cohort of 100 consecutive cases, the system effectively coapted the skin flap in all patients without major complications. Clinical data revealed a mean drainage duration of 6 days and 19 h (95% CI: 6 d 11 h to 7 d 4 h) and a mean collected fluid volume of 17.36 mL (95% CI: 16.77–17.95 mL). Blinded expert evaluation using the weighted 13-point Sharma scale demonstrated “Excellent” framework definition in 81.7% of patients. This system offers exceptional reliability and disruptive cost-efficiency, achieving stable vacuum pressure at a production cost of approximately 0.60 USD. These findings provide a compelling proof-of-concept for an accessible, high-performance alternative in auricular reconstruction, establishing a robust foundation for broader clinical adoption and future comparative validation in resource-limited surgical settings.