Answers are grounded in this paper and cite their sources.
Cohort study demonstrates that the RISK-E calculator predicts surgical mortality in active infective endocarditis, suggesting superior accuracy compared to standard risk scores.
OBJECTIVE: To develop and validate a calculator to predict the risk of in-hospital mortality in patients with active infective endocarditis (IE) undergoing cardiac surgery. Finally, an external validation of the RISK-E in a separate population was done. RESULTS: or fungi infection, acute renal failure, septic shock, cardiogenic shock and thrombocytopaenia. Area under the receiver operating characteristic curve in the validation sample was 0.82 (95% CI 0.75 to 0.88). The accuracy of the other surgical scores when compared with the RISK-E was inferior (p=0.010). Our score also obtained a good predictive performance, area under the curve 0.76 (95% CI 0.64 to 0.88), in the external validation. CONCLUSIONS: IE-specific factors (microorganisms, periannular complications and sepsis) beside classical variables in heart surgery (age, haemodynamic condition and renal failure) independently predicted perioperative mortality in IE. The RISK-E had better ability to predict surgical mortality in patients with IE when compared with other surgical scores.
No takes yet. Share an insight, caveat, or question.
Olmos et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: