This SDR scatterometer shows improved signal-to-noise ratio in real-time soil moisture measurements, indicating effective vegetation monitoring.
Ground-based scatterometers are widely used for quantitative microwave backscattering measurements in soil moisture retrieval, vegetation monitoring, and satellite scatterometer validation. However, low-cost software-defined radio (SDR) transceivers provide limited instantaneous bandwidth, making it difficult to transmit and process signals with bandwidths on the order of hundreds of MHz for fine range resolution, especially for systems requiring real-time onboard processing. To address this problem, this paper presents a vehicular, fully polarimetric, SDR-based scatterometer that achieves an equivalent wideband response by sequentially transmitting adjacent narrow subbands and coherently synthesizing them onboard. To enable real-time operation on a resource-limited field-programmable gate array/system-on-chip (FPGA/SoC) platform, we adopt a frequency-domain synthesis-pulse-compression pipeline that avoids interpolation and eliminates repeated matched filtering across subbands. A slot-based online phase calibration is performed within the settling window after each fast lock to estimate and compensate random local oscillator (LO) phase offsets, preserving coherent stitching. In addition, pulse repetition within each subband and coherent accumulation are integrated to improve the signal-to-noise ratio (SNR) under real-time throughput constraints. A Zynq-based implementation demonstrates deterministic onboard range-profile output, with a minimum processing latency of about 1.57 ms per frame. Loopback and outdoor experiments validate the equivalent 200 MHz bandwidth (five 40 MHz subbands), achieving approximately 0.75 m resolution and yielding sidelobe metrics consistent with the designed windowing, including a peak sidelobe ratio (PSLR) of −27.43 dB and an integrated sidelobe ratio (ISLR) of −12.38 dB. Field scans over farmland further show consistent σ0 trends across incidence angle and azimuth, indicating reliable onboard quantitative backscattering measurement. These results demonstrate that the proposed method provides a feasible solution for deterministic real-time equivalent wideband scatterometry on a low-cost SDR platform.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: