Ten high-strength concrete slabs reinforced with a new type of steel fiber, double-hooked-end steel fibers, were tested under punching shear loads. The strength of the concrete f c varied from 80 to 100 MPa (11,600 to 14,500 psi). The fiber content V f varied from 0 to 1.2%. Two different values of flexural reinforcement ratios (= A s / bd) of 0.9% and 1.4% were chosen for this test program. The experimental results showed that the use of double-hooked-end steel fibers in concrete enhances slab performance significantly in many ways. As the fiber volume or fiber content V f increased, the flexural stiffness of the slab throughout loading history also increased, while both the deflections and crack widths decreased considerably. At the ultimate load stage, the punching shear strength increased by up to 156% compared to non-fibrous concrete slabs. The increase in punching shear strength is significantly higher than the increase introduced by conventional single hooked-end steel fibers. The ductility of the slabs was also significantly improved.