PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 10, 20260 citationsOpen Access

Improving Damping of Generator Oscillations via Optimized HVDC Link Placement in Power Systems

View Full Paper
AAAyodele Kehinde AfolabiLadoke Akintola University of Technology

Key Points

  • This research aims to evaluate the impact of HVDC link placement on generator oscillation damping in power systems during disturbances.
  • Evaluated transient stability using swing equations technique.
  • Employed Line-Voltage Stability Index (L-VSI) to select critical buses during contingencies.
  • Performs simulations in MATLAB R2023a using data sets from IEEE 30-bus systems.
  • Placing HVDC improved the generator oscillation damping ratio stability significantly.
  • The approach resulted in reduced total active power losses and total cost of controllers.

Abstract

Application of Voltage Source Converter (VSC) such as High Voltage Direct Current (HVDC) has been widely recognized as one of the most advanced and powerful tools in providing a veritable way to control the transient instability in power system. However, the effect of this device on power system generator oscillation damping ratio during contingency need to be examined for effective system planning and monitoring. This research paper evaluates the effect of placing HVDC on the stability of power system generator oscillation damping ratio in order to improve the system stability during disturbance. Transient stability of electrical power system with contingency was performed using swing equations technique. Critical buses in the system at contingency was selected using Line-Voltage Stability Index (L-VSI) technique An HVDC VSC was incorporated in the power system and its effect on stability of the generator oscillation damping ratio at the contingency was investigated. Simulation was done in MATLAB R2023a. The approach was evaluated with data sets of IEEE 30-bus systems. Generator damping ratio, total active power losses and total cost of controllers were determined. The results revealed that placing HVDC in the power system improved the system generator oscillation damping ratio stability and has positive impact (stability) on electric power system.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ayodele Kehinde Afolabi (2025) studied this question.

synapsesocial.com/papers/6a0021e6c8f74e3340f9ccebhttps://doi.org/10.5281/zenodo.20082190