Methods of controllable, noncontact rotation of optically trapped microscopic objects have garnered significant attention for tomographic imaging and microfluidic actuation. Here, we report development of a fiber-optic spanner and demonstrate controlled rotation of smooth muscle cells. The rotation is realized by introducing a transverse offset between two counterpropagating beams emanating from single-mode optical fibers. The rotation speed and surrounding microfluidic flow could be controlled by varying balanced laser beam powers. Further, we demonstrate simultaneous translation and rotation of the fiber-optically trapped cell by varying the laser power of one fiber-optic arm.
No takes yet. Share an insight, caveat, or question.
Black et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: