Why the study?
Clinical outcomes comparing Watchman vs. Amplatzer devices for left atrial appendage closure needed evaluation.
Does the Watchman device compared to the Amplatzer device improve efficacy and safety in patients undergoing left atrial appendage closure?
Does the Watchman device compared to the Amplatzer device improve efficacy and safety in patients undergoing left atrial appendage closure?
Watchman and Amplatzer devices demonstrate comparable efficacy and safety profiles for left atrial appendage closure in a real-world propensity-matched cohort.
Answers are grounded in this paper and cite their sources.
Supports individualized device selection in LAA closure; leaves open whether randomized trials would detect efficacy or safety differences.
AIMS: This study compares clinical outcomes of Watchman vs. Amplatzer devices for left atrial appendage closure (LAAC). METHODS AND RESULTS: Of two real-world registries, the Watchman registry Lichtenfels, Germany, and the Amplatzer registry Bern-Zurich, Switzerland, 303 and 333 consecutive patients, respectively, were included. After a 1:1 propensity score matching, 266 vs. 266 patients were compared by use of the predefined primary efficacy endpoint of stroke, systemic embolism and cardiovascular/unexplained death, the primary safety endpoint of major peri-procedural complications and major bleeding events at follow-up, and the combined hazard endpoint, a composite of all above-mentioned hazards. Mean age was 75.3 ± 7.8 (Watchman) vs. 75.1 ± 9.9 (Amplatzer) years, CHA2DS2-VASc score 4.5 ± 1.7 vs. 4.5 ± 1.5, and HAS-BLED score 3.2 ± 1.0 vs. 3.2 ± 1.0. At a mean follow-up of 2.4 ± 1.3 vs. 2.5 ± 1.5 years and 1.322 patient-years, the primary endpoints of efficacy [40/646, 6.2% [Watchman] vs. 43/676, 6.4% [Amplatzer]; hazard ratio (HR), 1.02; 95% confidence interval (CI), 0.66-1.58; P = 0.92] and safety (33/646, 5.1% vs. 30/676, 4.4%; HR, 0.57; 95% CI, 0.29-1.11; P = 0.10), as well as the combined hazard endpoint (69/646, 10.7% vs. 66/676, 9.8%; HR, 0.80; 95% CI, 0.55-1.12; P = 0.26) were similar for both groups. CONCLUSION: This study suggests comparable efficacy and safety of the Watchman and Amplatzer devices.
No takes yet. Share an insight, caveat, or question.
Kleinecke et al. (2020) studied this question.