In this paper, the deployment of a newly developed, multipoint, fiber-optic temperature-sensor system for temperature distribution measurements in a 6 MW gas turbine is demonstrated. The optical sensor fiber was integrated in a stainless steel protection cable with a 1.6 mm outside diameter. It included six measurement points, distributed over a length of 110 mm. The sensor cable was mounted in a temperature probe and was positioned radially in the exhaust-gas diffusor of the turbine. With this temperature probe, the radial temperature profiles in the exhaust-gas diffusor were measured with high spatial and temporal resolution. During a test run of the turbine, characteristic temperature gradients were observed when the machine operated at different loads.
No takes yet. Share an insight, caveat, or question.
Dutz et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: