in the AI plans was comparable to KBP and clinic plans without statistical significance. The whole body (BODY) D1cc and rectum D0.1cc of AI plans were slightly higher (<1 Gy) compared to KBP and clinic plans; in contrast, the bladder D1cc and other rectum and bladder low doses in the AI plans were slightly improved without clinical relevance. The overall isodose distribution in the AI plans was comparable with KBP plans and clinical plans. AIP-SFFP generated each test plan within 20s including the prediction and the dose calculation. In conclusion, AIP-SFFP was successfully developed for prostate IMRT planning. AIP-SFFP demonstrated good overall plan quality and real-time efficiency. Showing great promise, AIP-SFFP will be investigated for immediate clinical application.
No takes yet. Share an insight, caveat, or question.
Li et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: