Answers are grounded in this paper and cite their sources.
PURPOSE: To evaluate the benefits of an artificial intelligence (AI)-based tool for two-dimensional mammography in the breast cancer detection process. MATERIALS AND METHODS: In this multireader, multicase retrospective study, 14 radiologists assessed a dataset of 240 digital mammography images, acquired between 2013 and 2016, using a counterbalance design in which half of the dataset was read without AI and the other half with the help of AI during a first session and vice versa during a second session, which was separated from the first by a washout period. Area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and reading time were assessed as endpoints. Reading time changed dependently to the AI-tool score. For low likelihood of malignancy (< 2.5%), the time was about the same in the first reading session and slightly decreased in the second reading session. For higher likelihood of malignancy, the reading time was on average increased with the use of AI. CONCLUSION: © RSNA, 2020.
No takes yet. Share an insight, caveat, or question.
Pacilè et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: