AIM: This prospective, observational cohort study aimed to measure HbA1c change over 3-6 months in type 2 diabetes managed with basal-bolus insulin and FreeStyle Libre® Flash Glucose Monitoring System (FSL) use compared to self-monitored blood glucose (SMBG). METHODS: Sixteen Italian hospitals enrolled patients with type 2 diabetes (n = 322, [109 FSL, 213 SMBG users]) using basal-bolus insulin therapy for ≥ 1 year, HbA1c 8.0-12.0% (64-108 mmol/mol), new to FSL use (<3 months) or continuing with SMBG (controls). Eligible FSL and SMBG users were matched (1:2 ratio) for baseline HbA1c (within ± 0.5%, recorded ≤ 3 months previously), study site and baseline data collection date. RESULTS: and insulin use duration 8.6 ± 6.6 years (mean ± SD), 56.2% were males. After 3-6 months, 234 complete cases (83 FSL, 151 SMBG users) demonstrated significantly reduced HbA1c for FSL use compared to SMBG (0.3% ± 0.12 [3 mmol/mol ± 1.3, (mean ± SE)], p = 0.0112). The difference remained statistically significant after adjusting for confounders. CONCLUSIONS: HbA1c significantly improved in basal-bolus treated type 2 diabetes after flash glucose monitoring use for 3-6 months compared to SMBG.
No takes yet. Share an insight, caveat, or question.
Bosi et al. (2021) studied this question.