Highlights the importance of using TEE when clinical suspicion for infective endocarditis remains high despite a negative TTE, even with rare entry points like penile implant infections.
INTRODUCTION: is a Gram-positive bacteria and is the most common cause of endocarditis. CASE PRESENTATION: (MSSA). A transthoracic echocardiogram (TTE) was performed due to concern for infective endocarditis (IE) but did not show any valvular abnormalities. Due to high clinical suspicion, a transesophageal echocardiogram (TEE) was performed and revealed a vegetation on the native mitral valve. His penile implant was removed by urology and intraoperative cultures grew MSSA. Surgical valve replacement was not recommended, and the patient was sent home with IV antibiotics for 6 weeks. DISCUSSION: Post-operative site infections are a quite uncommon point of entry for infective endocarditis, with penile implant infections being an even rarer cause. While a TTE is often used initially to attempt to diagnose infective endocarditis, it has lower sensitivity than a TEE. If clinical suspicion for infective endocarditis remains high after negative imaging with TTE, then TEE should be performed for better visualization of the heart valves.
No takes yet. Share an insight, caveat, or question.
Creel et al. (2021) studied this question.