PURPOSE: To determine normative R2* values in the liver and heart at 3T, and establish the relationship between R2* at 3T and 1.5T over a range of tissue iron concentrations. MATERIALS AND METHODS: A total of 20 healthy control subjects and 14 transfusion-dependent patients were scanned at 1.5T and 3T. At each field strength R2* imaging was performed in the liver and heart. RESULTS: Normative R2* values in the liver were estimated from the control group to be 39.2 +/- 9.0 second(-1) at 1.5T and 69.1 +/- 21.9 second(-1) at 3T. Normative cardiac values were estimated as 23.4 +/- 2.2 second(-1) at 1.5T and 30.0 +/- 3.7 second(-1) at 3T. The combined R2* data from patients and control subjects exhibited a linear relationship between 3T and 1.5T. In the liver, the line of best fit to the 3T vs. 1.5T data had a slope of 2.00 +/- 0.06 and an intercept of -11 +/- 4 second(-1). In the heart, it had a slope of 1.88 +/- 0.14 and an intercept of -15 +/- 4 second(-1). CONCLUSION: These preliminary data suggest that the iron-dependent component of R2* scales linearly with field strength over a wide range of tissue iron concentrations. The incidence of susceptibility artifacts may, however, also increase with field strength.
No takes yet. Share an insight, caveat, or question.
Storey et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: