Why the study?
ECMO circuit volume, patient size, and blood flow may influence coagulation and hemolysis complications, but their clinical impact in pediatric patients needed evaluation.
Do circuit size, patient size, and ECMO type influence coagulation and hemolysis complications in pediatric ECMO patients?
Do circuit size, patient size, and ECMO type influence coagulation and hemolysis complications in pediatric ECMO patients?
Answers are grounded in this paper and cite their sources.
In pediatric ECMO, respiratory indication and higher circuit-to-patient volume ratios are associated with increased coagulation and hemolysis complications, which in turn increase hospital mortality.
Extracorporeal membrane oxygenation (ECMO) circuit volume, patient size, and blood flow may influence coagulation and hemolysis complications. We performed a single-center retrospective analysis of ECMO patients over a 6.5 year period. In 299 ECMO runs, 13% required coagulation-associated circuit changes. Respiratory ECMO was associated with coagulation-associated circuit changes [odds ratio (O/R) 2.8, p < 0.05] and developed severe (plasma-free hemoglobin [pfHb] > 100 mg/dl) hemolysis (O/R 2.3, p < 0.05). Severe hemolysis and component changes were associated with hospital mortality (O/R 2.3 and 2.5, respectively, p < 0.05). The activated partial thromboplastin time (aPTT) to residence time (RT) ratio (aPTT/RT) was used as a surrogate for coagulation risk. We found that aPTT/RT > 2.5 more than doubled time to circuit change (3-8 days, p < 0.05), but aPTT/RT > 3 increased bleeding risks and hospital mortality (O/R 1.8; p < 0.1). Hemolysis was associated with patient weight and circuit to patient volume ratio (CPVR) (p < 0.05), but not pump type. Hemolysis slightly increased with transfusion (p = 0.08), and transfusion requirements increased for CPVR >50% (p < 0.1).Our data suggest that pediatric respiratory ECMO patients are more likely to develop coagulation and hemolysis complications, which are associated with increased mortality. This may result from higher inflammatory processes, which affect coagulation and red cell fragility. Minimizing circuit volume, inflammation, and red cell stress may help to reduce these two complications and their associated mortality.
No takes yet. Share an insight, caveat, or question.
Maul et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: