January 27, 2012Magnetic Resonance in Medicine114 citationsOpen Access

Informed RESTORE: A method for robust estimation of diffusion tensor from low redundancy datasets in the presence of physiological noise artifacts

View Full Paper
LCLin‐Ching ChangLWLindsay WalkerCPCarlo Pierpaoli

Key Points

Key points are not available for this paper at this time.

Abstract

Physiological noise artifacts, especially those originating from cardiac pulsation and subject motion, are common in clinical Diffusion tensor-MRI acquisitions. Previous works show that signal perturbations produced by artifacts can be severe and neglecting to account for their contribution can result in erroneous diffusion tensor values. The Robust Estimation of Tensors by Outlier Rejection (RESTORE) method has been shown to be an effective strategy for improving tensor estimation on a voxel-by-voxel basis in the presence of artifactual data points in diffusion-weighted images. In this article, we address potential instabilities that may arise when using RESTORE and propose practical constraints to improve its usability. Moreover, we introduce a method, called informed RESTORE designed to remove physiological noise artifacts in datasets acquired with low redundancy (less than 30-40 diffusion-weighted image volumes)--a condition in which the original RESTORE algorithm may converge to an incorrect solution. This new method is based on the notion that physiological noise is more likely to result in signal dropouts than signal increases. Results from both Monte Carlo simulation and clinical diffusion data indicate that informed RESTORE performs very well in removing physiological noise artifacts for low redundancy diffusion-weighted image datasets.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Chang et al. (2012) studied this question.

synapsesocial.com/papers/6a03eb3750d3ed7cf32b362ehttps://doi.org/10.1002/mrm.24173
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effects of physiological noise in population analysis of diffusion tensor MRI data2010 · 62 citations
  2. 2Variance of estimated DTI‐derived parameters via first‐order perturbation methods2006 · 42 citations
  3. 3Data Reduction and Error Analysis for the Physical Sciences1993 · 13,769 citations
  4. 4Outliers in Statistical Data1979 · 2,844 citations
  5. 5Anisotropy of NMR properties of tissues1994 · 430 citations