Answers are grounded in this paper and cite their sources.
A method quantifies vanadium levels in various biological and environmental samples, indicating high sensitivity and specificity.
Highly sensitive and selective direct spectrophotometric method is proposed for the determination of aluminium in various real samples. 5- methoxy-2-[[(4-methoxy-3, 5-dimethyl-2-pyridinyl] methyl] sulfinyl]-1HBenzimidazole reacts with V(V) forming greenish yellow coloured soluble complex in aqueous dimethyl formamide which has a λmax at 410 nm in the pH range 4.0-7.0. The system obeyed Beer’s law in the range 0.508 – 0.854 μg mL-1 of V (V). The molar absorptivity is 2.65 x 104 L mol-1 cm-1 and The Sandell’s sensitivity is 0.0825 μg/cm2. The standard deviation of the method for ten determinations of 0.579 μg/ml of V (V) is 0.0086. The correlation coefficient (γ) of the calibration equation of the experimental data is 0.9897.Studies on effect of diverse ions showed almost all the anions a majority of the cations do not interfere in more than 30 fold excess. The direct method was applied for the determination of vanadium biological samples like cabbage leaves and Goat leaves, blood and urine samples Tap water and plant materials.
No takes yet. Share an insight, caveat, or question.
Srinivasulu Narayana Chittibabu (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: