PURPOSE: The aim of this study was to evaluate the effects of various surface treatments on the surface structure and shear bond strength (SBS) of different ceramics. MATERIALS AND METHODS: particles and silanization (Clearfil Porcelain Bond Activator); HF-etching in 5% hydrofluoric acid and silanization; ER-etching with an Er:YAG laser (10 W); ND-Nd:YAG laser etching (0.8 W); and FS-etching with a femtosecond laser (860 mW). A luting cement (Clearfil Esthetic) was photopolymerized on each treated ceramic disk. After subjecting the specimens to thermocycling (1000 cycles, 5°C to 55°C), SBS tests were performed using a universal testing machine. The data were analyzed with two-way ANOVA and Tukey's tests using a significance limit of 5%. RESULTS: Among the EX ceramics, the CJ (29.10 MPa) and HF (26.07 MPa) specimens had statistically higher SBS values. For the ICZ ceramics, the highest value (28.08 MPa) was obtained for the CJ specimens. CONCLUSIONS: Silanization after coating with silica improves the bond strengths of both EX and ICZ specimens, while HF etching is favorable only for the EX specimens.