Key result
Pre-procedural elevated plasma asymmetric dimethylarginine (ADMA) level independently increased the risk of restenosis 6 months after bare metal stenting (OR 5.96).
Why the study?
Does pre-procedural elevated plasma ADMA level predict restenosis in patients with stable coronary artery disease undergoing coronary angioplasty with bare metal stents?
Cohort (n=60)
Blinded outcome assessment
No
Does pre-procedural elevated plasma ADMA level predict restenosis in patients with stable coronary artery disease undergoing coronary angioplasty with bare metal stents?
Effect estimate: OR 5.96 (95% CI 2.45, 11.26)
p-value: p=< 0.01
Pre-procedural elevated plasma ADMA level is an independent predictor of angiographic restenosis 6 months after bare metal stent implantation.
Elevated pre-procedural ADMA may flag higher restenosis risk after bare metal stenting; hypothesis-generating and should not yet change practice.
INTRODUCTION: Asymmetric dimethylarginine (ADMA) is an endogenous competitive inhibitor of endothelial nitric oxide synthase. Asymmetric dimethylarginine may influence the process of restenosis after coronary angioplasty. The aim of the study was to determine if initial plasma ADMA level could predict restenosis after coronary angioplasty and stenting. MATERIAL AND METHODS: The study group consisted of 60 consecutive patients (10 women and 50 men, average age 58.9 ±10.4 years old), who underwent percutaneous coronary angioplasty with bare metal stenting for stable coronary artery disease. All patients underwent follow-up coronary angiography after a 6-month period. Patients were divided into two groups, one with restenosis (n = 22), and the other one without restenosis (n = 38). In addition to measuring acknowledged restenosis risk factors, plasma ADMA level was measured before initial angiography. RESULTS: Asymmetric dimethylarginine plasma level was significantly higher in the group with restenosis than in the group without restenosis (1.94 ±0.94 µmol/l vs. 0.96 ±0.67 µmol/l; p < 0.05). L-arginine/ADMA ratio was also decreased in the group with restenosis, when compared with the group without restenosis (p < 0.05). Multivariate logistic regression revealed that independent restenosis risk factors were characterised by an initially high ADMA level (p < 0.01), advanced age (p < 0.05) and low level of HDL cholesterol (p < 0.05). CONCLUSIONS: Pre-procedural elevated plasma ADMA level increases the risk of restenosis in patients who underwent coronary angioplasty and stenting with bare metal stents.
No takes yet. Share an insight, caveat, or question.
Derkacz et al. (2011) conducted a cohort in Stable coronary artery disease (n=60). Elevated plasma asymmetric dimethylarginine (ADMA) vs. Lower plasma ADMA level was evaluated on Restenosis at 6 months (OR 5.96, 95% CI 2.45, 11.26, p=< 0.01). Pre-procedural elevated plasma asymmetric dimethylarginine (ADMA) level independently increased the risk of restenosis 6 months after bare metal stenting (OR 5.96).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: