Why the study?
Biological composite valve grafts are performed increasingly often, but the feasibility of future valve-in-valve procedures to treat bioprosthetic valve failure in this population remains uncertain.
Does bioprosthetic composite valve graft implantation alter aortic root geometry and coronary height in a way that increases risk for coronary obstruction in future valve-in-valve procedures?
Does bioprosthetic composite valve graft implantation alter aortic root geometry and coronary height in a way that increases risk for coronary obstruction in future valve-in-valve procedures?
Bioprosthetic composite valve graft implantation significantly decreases coronary height, placing a majority of patients at risk for coronary obstruction during future valve-in-valve procedures.
May increase future valve-in-valve obstruction risk after CVG; hypothesis-generating and requires prospective confirmation.
OBJECTIVES: Biological composite valve grafts (CVGs) are being performed more frequently, which increases the need for interventions treating bioprosthetic valve failure. The feasibility of valve-in-valve procedures in this population is uncertain. This study aimed to assess changes in aortic root geometry and coronary height following CVG implantation to better understand future interventions. METHODS: We retrospectively identified 64 patients following bioprosthetic CVG replacement with pre- and postoperative computed tomography angiography. Root assessment was conducted as in preprocedural transcatheter aortic valve evaluation using a virtual valve simulation. RESULTS: In 64 patients (age, 67.6 ± 9.3 years; 76.6% men) the preoperative coronary height was 14.3 ± 6.8 mm for the left coronary artery (LCA) and 17.9 ± 5.9 mm for the right coronary artery (RCA), which significantly decreased after CVG implantation, with 8.7 ± 4.4 mm for the LCA and 11.3 ± 4.4 mm for the RCA (P < .001). The virtual valve-to-coronary distances measured 4.0 ± 1.3 mm (LCA) and 4.6 ± 1.4 mm (RCA). Overall, 59.4% (n = 38) of patients with bio-CVGs would have been at risk for coronary obstruction, 29.7% (n = 19) for LCA, 10.9% (n = 7) for RCA, and 18.8% (n = 12) for combined LCA and RCA. CONCLUSIONS: Coronary height significantly decreased following CVG implantation. The majority of patients after bio-CVG were at a potential risk for coronary obstruction in future valve-in-valve procedures. Further studies are needed to identify the best possible technique for coronary reimplantation and other measures to diminish the risk for future coronary obstruction in this population.
No takes yet. Share an insight, caveat, or question.
Werner et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: