Psychometric study validates the Troy Sleep Scale for screening sleep complaints in adults, suggesting a cut-off for clinical use.
Sleep complaints are common and clinically consequential, highlighting the need for brief multidimensional screening tools. The Troy Sleep Scale (TSS) was previously developed in a non-clinical sample; this study aimed to validate the TSS in a clinical sample and estimate a screening threshold based on subjective sleep-complaint status. This case–control psychometric study included 434 adults, comprising 272 participants with subjective sleep complaints and 162 healthy controls. Participants completed the 11-item TSS, which includes three subscales, and established comparator measures of sleep disturbance, daytime sleepiness, and anxiety/depression symptoms. Reliability was assessed using internal consistency, item analyses, and 2–4-week test–retest reliability in a subsample (n = 172). Structural validity was examined with ordinal confirmatory factor analysis based on polychoric correlations. Construct validity was evaluated through convergent, discriminant, known-groups, and covariate-adjusted analyses. ROC/AUC analysis with Youden’s index was used to estimate a sample-derived screening threshold, and item response theory (IRT) assessed item-level functioning. Internal consistency was excellent (α = 0.952; ω = 0.950), with high corrected item–total correlations (0.717–0.833). Test–retest reliability was moderate for the total score (ICC = 0.629) and good for subscales (ICC = 0.728–0.803). Ordinal CFA supported the three-factor structure with excellent fit (SRMR = 0.028; robust RMSEA = 0.032; robust CFI = 0.998; robust TLI = 0.997) and high standardized loadings. TSS scores correlated significantly with comparator sleep measures (r = 0.631–0.838; Holm-corrected p < 0.004), and associations remained significant after controlling for HADS. Known-groups validity was strong, including after covariate adjustment (partial η²=0.236), and discriminant validity was supported (HTMT = 0.762–0.870). ROC analysis showed excellent discrimination (AUC = 0.931); a threshold of ≥ 24 yielded sensitivity = 0.873 and specificity = 0.851. IRT analyses further supported item-level performance. The TSS demonstrated robust reliability, strong construct validity, and promising screening utility in this clinical sample. The provisional sample-derived threshold of ≥ 24 may support screening and triage of sleep complaints, but requires external validation against rigorous clinical reference standards.
No takes yet. Share an insight, caveat, or question.
Korkmaz et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: