Demonstrates improved rehabilitation exercise accuracy in stroke patients, suggesting effective monitoring tools.
This paper presents an approach for monitoring exercises of hand rehabilitation for past stroke patients. The developed solution uses a Leap Motion controller as hand-tracking device and embeds a supervised Machine Learning methodology. Support Vector Machine (SVM) is used in order to assess the correctness of a set of simple rehabilitation exercises performed with a single hand. The basic SVM model was extended with particular interest for defining feature vectors in a continues environment. The proposed method incorporated leap motion data, normalization of angles and gesture recognition. A software system was developed to provide patients with a set of exercise corrections and guidance for rehabilitation.