Why the study?
The 1-year efficacy and safety of a novel cryoballoon ablation system compared with the standard cryoballoon system for pulmonary vein isolation needed comparison.
Does a novel cryoballoon ablation system improve 1-year efficacy and safety compared to a standard cryoballoon system in patients with atrial fibrillation undergoing pulmonary vein isolation?
Does a novel cryoballoon ablation system improve 1-year efficacy and safety compared to a standard cryoballoon system in patients with atrial fibrillation undergoing pulmonary vein isolation?
The novel POLARx cryoballoon ablation system demonstrated comparable 1-year efficacy and safety to the standard Arctic Front system for pulmonary vein isolation in patients with atrial fibrillation.
Comparable efficacy observed with novel versus standard cryoballoon; leaves open advantages and should not yet change practice without RCTs.
AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.
No takes yet. Share an insight, caveat, or question.
Knecht et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: