Key result
Fetal magnetocardiogram current-arrow maps and phase differences successfully identified very weak prolonged T waves in 2 abnormal fetuses, despite T/QRS ratios showing a wide variability of 0.35.
Why the study?
Does fetal magnetocardiogram using current-arrow maps and phase differences improve the determination of the T wave and diagnosis of QT prolongation in fetuses?
Observational (n=54)
Does fetal magnetocardiogram using current-arrow maps and phase differences improve the determination of the T wave and diagnosis of QT prolongation in fetuses?
Fetal magnetocardiogram using current-arrow maps and phase differences can effectively detect weak T waves and diagnose prenatal QT prolongation.
Supports current-arrow maps for weak T-wave detection in fetal magnetocardiography despite T/QRS variability; leaves open prospective validation for QT prolongation diagnosis.
To determine the T wave of a fetal magnetocardiogram (FMCG), we have evaluated the T/QRS ratio and obtained current-arrow maps that indicate weak currents. We measured FMCG signals for 52 normal fetuses and two abnormal fetuses with prolonged QT waves by using three superconducting quantum interference device (SQUID) systems: a nine-channel system, a 12-channel vector system and a 64-channel system. The T/QRS ratio was calculated for all the normal fetuses from the maximum magnitudes of the QRS complex and the T wave. Current-arrow maps of the QRS complex (R wave) and T wave were obtained by using the 64-channel system, and the phase differences of the total-current vectors were calculated by using the current-arrow maps. The results showed that the T/QRS ratio had a wide variability of 0.35 for the normal fetuses. However, the magnitude of the prolonged T wave was as weak as the detection limit of the SQUID magnetometer. Although the T/QRS ratios for the fetuses with QT prolongation were within the normal range (< 0.35), the weak magnitude of the prolonged T wave could be evaluated. On the other hand, by comparing the current-arrow maps of the R and T waves for the normal fetuses, we found that the maximum-current arrows were indicated as either in the same direction or in opposite directions. These patterns could be identified clearly by the phase differences. Very weak prolonged T waves for the two abnormal fetuses could be determined by using these current-arrow maps and phase differences. Consequently, although the T/QRS ratios of FMCG signals have a wide distribution, we have concluded that the current-arrow map and phase difference can be used to determine the T wave of an FMCG signal.
No takes yet. Share an insight, caveat, or question.
Kandori et al. (2001) conducted an observational in Fetal QT prolongation (n=54). Fetal magnetocardiogram (FMCG) using current-arrow maps was evaluated on Determination of the T wave and T/QRS ratio. Fetal magnetocardiogram current-arrow maps and phase differences successfully identified very weak prolonged T waves in 2 abnormal fetuses, despite T/QRS ratios showing a wide variability of 0.35.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: