Coherent anti-Stokes emission has been observed for resonance excitation of NO2 within an optical pumping geometry similar to that employed for CARS spectroscopy. Spectra have been measured for excitation of NO2 in three wavelength regions of its absorption: 585, 564, and 542 nm. These spectra have been used to investigate the four wave process which produces this emission and to determine the ro–vibronic contributions to the absorption of NO2 at these wavelengths. Results from pressure quenching and time dependence studies indicate that a coherent level is produced which has a relatively long lifetime. The anti-Stokes emission has the same temporal properties as the Stokes pulse. This indicates that only the first pump photon is in resonance with an electronic transition. A comparison of these results with those expected for resonance Raman and discrete resonance Raman in particular indicates that the resonance CARS process can be interpreted by theoretical and phenomenological considerations developed to describe resonance Raman.
No takes yet. Share an insight, caveat, or question.
McIlwain et al. (1980) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: