Key result
Noninvasive pulse wave measurement detects cerebral artery occlusions with ~65% diagnostic accuracy.
Why the study?
Rapid reperfusion therapy reduces disability and death in LVOS, making it crucial for emergency medical services to identify LVOS and transport patients directly to a comprehensive stroke center.
Does a non-invasive screening system using pulse wave measurements accurately detect carotid artery occlusion?
Observational (n=53)
Yes
Does a non-invasive screening system using pulse wave measurements accurately detect carotid artery occlusion?
A novel non-invasive screening system using pulse wave measurements shows potential for identifying carotid artery occlusions with a diagnostic accuracy of 0.65.
Answers are grounded in this paper and cite their sources.
May support noninvasive screening development; leaves open clinical utility pending larger validation studies.
Rapid reperfusion therapy can reduce disability and death in patients with large vessel occlusion strokes (LVOS). It is crucial for emergency medical services to identify LVOS and transport patients directly to a comprehensive stroke center. Our ultimate goal is to develop a non-invasive, accurate, portable, inexpensive, and legally employable in vivo screening system for cerebral artery occlusion. As a first step towards this goal, we propose a method for detecting carotid artery occlusion using pulse wave measurements at the left and right carotid arteries, feature extraction from the pulse waves, and occlusion inference using these features. To meet all of these requirements, we use a piezoelectric sensor. We hypothesize that the difference in the left and right pulse waves caused by reflection is informative, as LVOS is typically caused by unilateral artery occlusion. Therefore, we extracted three features that only represented the physical effects of occlusion based on the difference. For inference, we considered that the logistic regression, a machine learning technique with no complex feature conversion, is a reasonable method for clarifying the contribution of each feature. We tested our hypothesis and conducted an experiment to evaluate the effectiveness and performance of the proposed method. The method achieved a diagnostic accuracy of 0.65, which is higher than the chance level of 0.43. The results indicate that the proposed method has potential for identifying carotid artery occlusions.
No takes yet. Share an insight, caveat, or question.
Shimada et al. (2023) conducted an observational in Cerebral artery occlusion (n=53). Noninvasive pulse wave measurement and logistic regression inference vs. Chance level was evaluated on Diagnostic accuracy for identifying cerebral artery occlusions (p=<0.01). A noninvasive pulse wave measurement system using logistic regression achieved a diagnostic accuracy of 0.65 for identifying cerebral artery occlusions, significantly higher than the chance level of 0.43.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: