October 12, 2009IEEE Transactions on Industrial Electronics269 citations

Parameter Design of a Two-Current-Loop Controller Used in a Grid-Connected Inverter System With LCL Filter

View Full Paper
FLFei LiuYZYan ZhouSDShanxu Duan

Key Points

Key points are not available for this paper at this time.

Abstract

LCL filters offer a better choice of attenuating switching frequency harmonics. However, in a grid-connected system, an LCL filter may cause resonance which is a disaster for the system's stability. In order to solve the problem, a two-current-loop control strategy, which includes grid-current outer loop and filter-capacitor-current inner loop, is adopted here. The implementation of this strategy is easy, but the tuning procedure is complex since the outer and inner controllers cannot cooperate well if the parameters of the controllers are not suitable. There is no literature which mentions a method to help give out accurate parameters of the controller. The difficulty of designing the controller is that only two feedbacks cannot provide complete information of a three-order LCL filter. A specific method is proposed in this paper to design the controller. The advantage of this method is to provide a way to maximize the utilization of the two feedbacks to get good system performance through parameter determination. The practicability of the method is tested by using bode diagram, and the antidistortion ability of the system is analyzed. Finally, experimental results verify the availability and correctness of the proposed method.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Liu et al. (2009) studied this question.

synapsesocial.com/papers/6a08e64d27ceb0c2a2d615fehttps://doi.org/10.1109/tie.2009.2021175
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Stationary frame current regulation of PWM inverters with zero steady-state error2003 · 1,511 citations
  2. 2Renewable Energy Systems With Photovoltaic Power Generators: Operation and Modeling2008 · 443 citations
  3. 3Frequency-domain analysis of three-phase linear current regulators2001 · 606 citations
  4. 4Frequency domain analysis of three phase linear current regulators2003 · 578 citations
  5. 5A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter1997 · 511 citations