The requirements for high-performance pulse width modulation (PWM) at low switching frequency are defined. It is shown that the conversion of a continuous reference signal into a discrete switching sequence normally creates a modulation error at dynamic operation. This error is detected in an optical synchronous modulator using the steady-state current trajectory as a reference track in the transient state. A tracking controller eliminates the tracking error by modifying the switching pattern in real time. A parameter identification scheme enables the identification of the instantaneous fundamental current and the implementation of fast current regulators. Oscillograms from a 30-kW model drive demonstrate the high quality in forms of dynamic performance and minimum harmonic distortion obtained with a three-level inverter at only 200 Hz switching frequency.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Holtz et al. (2003) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: