Key result
Unacceptable tip-apex distance and lateral wall loss predict ~8% dynamic hip screw failure.
Why the study?
What are the rates of screw pull out and loss of lateral femoral wall integrity in patients with unstable intertrochanteric fractures treated with dynamic hip screw fixation?
Cohort (n=40)
No
What are the rates of screw pull out and loss of lateral femoral wall integrity in patients with unstable intertrochanteric fractures treated with dynamic hip screw fixation?
Unacceptable tip-apex distance and loss of lateral femoral wall integrity are indicators of DHS implant pull out, suggesting its use for unstable intertrochanteric fractures should be guarded.
Supports caution with DHS for unstable fractures; leaves open optimal fixation strategy in randomized trials.
Background: The treatment of unstable intertrochanteric fractures is challenging due to the difficulty in obtaining anatomical reduction. The purpose of this study was to analyse and use the parameters (lateral femoral wall integrity and tip-apex distance) in post-operative unstable intertrochanteric fractures treated using dynamic hip screw (DHS) fixation as guidelines for re-operation. Methods: This was a prospective study and included 40 patients with unstable intertrochanteric fractures treated using DHS fixation from December 2014 to September 2016. The AO/OTA classification was used to classify each of the patients and their lateral femoral wall integrity and tip-apex distance was assessed in the post-operative radiographs. Results: In this study, 3 patients out of 40 (7.5%) had screw pull out within 5 months of surgery. 2 pull outs occurred when the screw was in the antero-superior zone and 1 when it was in the centre to centre zone. Thus, the rate of screw pull out was higher in the antero-superior zone. The 3 patients with screw pull out had a mean tip-apex distance (TAD) of 36.01 mm as compared to 32.96 mm of those who did not have screw pull out. We further found that pre-operatively 6 patients out of 40 (15%) had lost lateral femoral wall integrity whereas post-operatively 26 patients out of 40 (65%) had lost it. In summary, there is a 5 times higher risk of losing lateral femoral wall integrity if DHS is the implant of choice. Conclusions: On conclusion, unacceptable TAD limit with loss of lateral femoral wall integrity was found to be a definite indicator of DHS implant pull out. And also found that by using the DHS as an implant of choice, there is a 5 times higher risk of losing lateral femoral wall integrity intra-operatively and that its use for the treatment of unstable intertrochanteric fractures must be guarded.
No takes yet. Share an insight, caveat, or question.
Aathipan et al. (2016) conducted a cohort in Unstable intertrochanteric fractures (n=40). Dynamic hip screw (DHS) fixation was evaluated on Screw pull out. Unacceptable tip-apex distance combined with loss of lateral femoral wall integrity was a definite indicator of dynamic hip screw implant failure, which occurred in 7.5% of patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: