Analysis reveals passive stent expansion affects clinical outcomes in patients with TIPS, suggesting critical implications.
We read with great interest the recent article by Roccarina et al. [1] which evaluates the impact of endoprosthesis under-dilation on the prevention of portal hypertension–related complications beyond primary TIPS indication. The authors conclude that under-dilated TIPS (U-TIPS) provides protection comparable to standard dilation, independent of achieving conventional hemodynamic targets. While this is an important and clinically relevant question, we believe that a key technical factor, namely passive expansion of the stent grafts used in the study, may significantly influence the interpretation of these findings. The study cohort predominantly utilised first-generation ePTFE-covered stent grafts (VIATORR), particularly during the earlier study period. These devices are composed of self-expanding nitinol, which exerts a continuous outward radial force. It is well established that such stents, even when initially under-dilated (e.g., 6–8 mm), tend to passively expand over time toward their nominal diameter [2, 3]. This phenomenon is intrinsic to nitinol and has been consistently demonstrated in both imaging-based and clinical follow-up studies. The implications of passive expansion are directly relevant to the authors' conclusions. If under-dilated stents progressively enlarge, the distinction between U-TIPS and standard TIPS (S-TIPS) may not be maintained during follow-up. As a result, a proportion of patients categorised as U-TIPS may ultimately function as larger shunts, thereby attenuating differences in portal decompression and clinical outcomes between groups. The reported equivalence between U-TIPS and S-TIPS may therefore reflect delayed convergence of effective shunt diameters rather than true independence from hemodynamic targets. This concern is supported by prior studies demonstrating that 10-mm nominal stents under-dilated to 8 mm frequently approach near-nominal diameters on follow-up, leading to progressive reductions in portal pressure gradient and increased shunt flow, with potential implications for both efficacy and complications such as hepatic encephalopathy [3]. The development of controlled-expansion stents (VIATORR-CX), designed to maintain a fixed diameter unless actively re-dilated, further underscores the clinical relevance of this issue [4]. Another limitation is the lack of serial post-TIPS portocaval pressure gradient measurements during follow-up. As the gradient is known to increase in the early post-procedural period, reliance on intraoperative values alone may result in misclassification of hemodynamic response, further complicating interpretation of the findings [5]. In summary, passive stent expansion and the absence of longitudinal hemodynamic assessment represent important unaddressed variables that may confound the study's conclusions. Accounting for these factors is essential before inferring that under-dilation is independent of clinical outcomes. The authors declare no conflicts of interest. This article is linked with http://doi.org/10.1111/liv.70606. Data sharing not applicable to this article as no datasets were generated or analysed during the current study.
No takes yet. Share an insight, caveat, or question.
Sasidharan et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: