Key result
3D RVEF ≤42% strongly predicts early right ventricular failure after LVAD implantation.
Why the study?
The study was conducted to determine predictors of early and late right ventricular failure using transthoracic echocardiography and right heart catheterisation in patients with left ventricular assist devices.
Do pre-implantation 3D-RVEF and PAPi predict right ventricular failure in patients undergoing LVAD implantation?
Observational (n=23)
No
Do pre-implantation 3D-RVEF and PAPi predict right ventricular failure in patients undergoing LVAD implantation?
Answers are grounded in this paper and cite their sources.
Pre-implantation 3D right ventricular ejection fraction and pulmonary artery pulsatility index are strong predictors of right ventricular failure after LVAD implantation.
Background. To determine predictors of early and late right ventricular failure (RVF) according to transthoracic echocardiography (TTEchoCG) and right heart catheterisation (RHC) in patients with left ventricular assist device (LVAD). Materials and methods. Twenty-three patients with LVAD were included in the study. Before implantation, all patients underwent TTEchoCG with comprehensive evaluation of the right ventricle (RV) using speckle-tracking echocardiography (STE) and 3D-echocardiography (3D-RVEF), as well as RHC with measurement of standard indices and calculation of pulmonary artery pulsatility index (PAPi). Results. The highest area under the ROC curve was the RV ejection fraction determined by 3D-RVEF (0.841 with 95% CI 0.677–1.006, sensitivity 0.889, specificity 0.786; p0.001) with a cut-off value ≤42% (OR 29.3 with 95% CI 2.6–336.4; p=0.007) and PAPi (area on ROC curve 0.869 with 95% CI 0.503–0.975, sensitivity 0.778, specificity 0.857; p0.001,) with a threshold value ≤2.2 (OR 20 with 95% CI 1.2–333.3; p=0.035). The combination of these parameters was the most accurate prognostic model (sensitivity 0.778, specificity 1). The combination of echocardiographic parameters – 3D-RVEF and systolic velocity of the tricuspid valve fibrous ring according to tissue myocardial Doppler (TMD: S’ml) has similar sensitivity (0.778) and slightly lower specificity (0.929). Conclusion. The optimal independent echocardiographic predictor of early RVF is 3D-RVEF. The combination of 3D-RVEF and PAPi proved to be the most accurate model, but the combination of 3D-RVEF and S’ml-TMD echocardiographic parameters alone is only slightly inferior in specificity, which allows preliminary assessment of the risk of RVF.
No takes yet. Share an insight, caveat, or question.
Shahramanova et al. (2025) conducted an observational in Heart failure requiring left ventricular assist device (LVAD) implantation (n=23). 3D right ventricular ejection fraction (3D-RVEF) assessment was evaluated on Early right ventricular failure (within 14 days post-implantation) (OR 29.3, 95% CI 2.6-336.4, p=0.007). A 3D right ventricular ejection fraction of ≤42% was the strongest independent echocardiographic predictor of early right ventricular failure after LVAD implantation (OR 29.3).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: