Key result
ASD and PDA closures achieve >98% procedural success, but success drops substantially for other congenital interventions.
Why the study?
What are the procedural success and safety rates of common interventional procedures in congenital heart disease?
Observational (n=4,152)
Yes
What are the procedural success and safety rates of common interventional procedures in congenital heart disease?
The IMPACT registry provides contemporary benchmarks for procedural success and safety of six common congenital interventional procedures.
BACKGROUND: The National Cardiovascular Data Registry (NCDR) launched the IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry in 2010. By 2013, its patient enrollment exceeded that of other current and historical congenital catheterization registries. OBJECTIVES: This study sought to describe procedural results and safety of 6 common congenital interventions performed in patients enrolled during the IMPACT Registry's initial periods. METHODS: With specified exclusions, we compiled registry data from patients enrolled in the IMPACT Registry from January 2011 through March 2013 who underwent 1 of the following isolated procedures: device closure of atrial septal defect (ASD); device closure of patent ductus arteriosus (PDA); pulmonary valvuloplasty; aortic valvuloplasty; coarctation of the aorta angioplasty and stenting; and pulmonary artery stenting. Patient data, procedural data and results, and adverse events (AEs) were reviewed and described. RESULTS: In 4,152 catheterizations, 1 isolated procedure was reported. There were 1,286 single-ASD procedures, 1,375 PDA procedures, 270 "typical" pulmonary valve procedures, 305 aortic valve procedures, 671 aortic procedures, and 245 pulmonary artery procedures. The reported procedure was performed in >95% of catheterizations. Stated outcomes were accomplished in >98% of ASD and PDA procedures, but less commonly in the others, with coarctation angioplasty procedures being the least successful (51%). Reported major AE rates ranged from 0% to 3.3%; total AE rates ranged from 5.3% to 24.3%. CONCLUSIONS: Contemporary community practice, procedural outcomes, and safety for 6 common congenital interventional procedures are reported. These benchmarks may be compared with individual center results and historical single-center and multicenter results.
No takes yet. Share an insight, caveat, or question.
Moore et al. (2014) conducted an observational in Congenital Heart Disease (n=4,152). Common congenital interventional procedures was evaluated on Procedural success and adverse events. In 4,152 catheterizations, procedural success was >98% for ASD and PDA closure but lower for others (51% for coarctation angioplasty), with major adverse event rates ranging from 0% to 3.3%.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: