The ability to determine the centre position of a localized temperature change within a chirped fibre Bragg grating (CFBG) has been investigated as a function of grating strength. The intragrating sensor is based on the analysis of reflected power spectra arising from a CFBG. The technique uses a discrete Fourier transform (FFT) in which the measured spectrum of the CFBG due to a localized temperature change (heat source) was simulated using a FFT grating design model. The model operated on the reference spectrum and hypothesis temperature distributions, T(z), to generate a spectrum of a CFBG subjected to a hypothesis temperature disturbance. The simulated spectrum was fitted to the measured spectrum using a three-parameter automatic disturbance function fitting algorithm operating on position, width and amplitude of temperature change. RMS deviations to within 0.03 mm of applied values of position have been obtained.
No takes yet. Share an insight, caveat, or question.
Nand et al. (2006) studied this question.