This is the authors' abstract. We don't add key points for this paper.
The coronavirus disease 2019 (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has led to substantial global mortality, emphasizing the need for rapid and sensitive detection. Reverse transcription–quantitative polymerase chain reaction (RT-qPCR), the current gold standard, is costly and time-consuming due to its complex procedures and resource requirements. In this study, a real-time split prism-assisted solution-immersed silicon (SP-SIS) aptasensor was developed for ultrasensitive and affordable detection of SARS-CoV-2 spike proteins. The newly designed split prism incorporates a thin metallic plate between optical components to reflect and absorb background noise originating from inner prism reflections. To enhance biosensing accuracy, the incident angle was precisely aligned with a low variation of ±0.005°, ensuring consistent optical performance across newly assembled sensors. Additionally, a surface with a controlled water contact angle significantly improved detection efficiency by promoting effective aptamer immobilization. The SP-SIS platform achieved detection limits of 76.8 fg/mL and 15.6 fg/mL for spike proteins, and 22.1 particles/mL and 28.7 particles/mL for virus-like particles, in viral transport medium and COVID-19-negative nasopharyngeal swab matrices, respectively. Moreover, it reliably detected SARS-CoV-2 variants and distinguished them from other coronaviruses, confirming high specificity. These findings demonstrate that the SP-SIS aptasensor provides a rapid, accurate, and ultrasensitive tool for early SARS-CoV-2 detection and can be extended to monitor emerging infectious diseases. • We developed a real-time SP-SIS aptasensor enabling ultrasensitive detection of SARS-CoV-2 spike proteins. • The split prism was designed with a thin metal plate between two optical components to eliminate background noise. • The incident angle was precisely aligned with a variation as low as ±0.005° for each newly attached sensor assembly. • We improved aptamer immobilization by tuning surface hydrodynamics, thereby enhancing detection efficiency. • The detection limits were 15.6 fg/mL for spike proteins and 28.7 particles/mL for virus-like particles.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: