February 1, 1976Circulation162 citations

Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application.

View Full Paper
JKJoseph KissloCardiac ImagingOVO T vonRammDurham Technical Community CollegeFTF. L. ThurstoneDuke University

Key Result

A new phased array two-dimensional ultrasound imaging system successfully produced high-resolution, real-time tomographic images of various cardiac structures including the left ventricle.

Structured PICO

Does a phased array two-dimensional ultrasound imaging system provide high-resolution real-time images of cardiac structures?

I
Intervention
Phased array two-dimensional ultrasound imaging system (hand-held linear array of 16 ultrasound transducers, 14 mm contact site)
O
Outcome
Delineation and high-resolution imaging of cardiac structuressurrogate

The development of a phased array two-dimensional ultrasound system enables high-resolution, real-time tomographic imaging of cardiac structures, representing a foundational advancement in echocardiography.

Abstract

A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures under investigation. A hand-held linear array of 16 ultrasound transducers with overall dimensions of 14 mm at the site of contanct may be readily manipulated to image various cardiac structures. The resulting images are displayed in a circular sector format, 60 degrees in azimuth and typically 15 cm in range. At his maximum range, image frames consisting of 256 lines are generated at the rate of 20 frames/second. High azimuthal resolution throughout the field of view is assured by a focused transmit beam and by sweeping the focus of the receiver is synchrony with the range of returning echoes. Azimuthal resolution varies from 2 to 5 mm throughout the field of view while range resolution is 1.5 mm. This imaging system has proven particularly useful for the delineation of left ventricular spatial geometry by the identification of endocardium, myocardium, papillary muscles and interventricular septum. High quality images of anterior and posterior mitral leaflets, aortic root and aortic leaflets as well as left atrium and other cardiac structures have been obtained.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kisslo et al. (1976) studied Cardiac imaging. Phased array two-dimensional ultrasound imaging system was evaluated on High resolution tomographic images of the heart in real time. A new phased array two-dimensional ultrasound imaging system successfully produced high-resolution, real-time tomographic images of various cardiac structures including the left ventricle.