Prospective observational study demonstrates improved accuracy in detecting regional V/Q mismatch using 3D-EIT compared to 2D-EIT in patients with focal lung disease.
Background Two-dimensional electrical impedance tomography (2D-EIT) is increasingly used at the bedside to monitor regional ventilation (V) and perfusion (Q). However, single-slice reconstruction may miss pathology localized outside the electrode plane. We hypothesised that three-dimensional EIT (3D-EIT) employing a dual-belt electrode configuration would improve the topographic accuracy of V/Q mismatch detection compared with conventional 2D-EIT. Methods In a prospective single-centre study (Zhongshan Hospital, Fudan University, February-June 2024) we enrolled 78 consecutive adults with known or suspected focal lung disease. Simultaneous recordings were obtained with: A custom 3D-EIT system (Infivision 1900, Huarui-Bio, China; 64 electrodes, two belts 4 cm apart) reconstructing a 12 × 12 × 8 cm³ lung volume;The belt supplying the second intercostal space exported as 2D-EIT data;A commercial 2D-EIT monitor (Dräger PulmoVista® 500, Germany) at the same level;Non-contrast thoracic CT acquired within 30 min. EIT images were segmented into six regions-of-interest (ROI, 3D) or four quadrants (2D). V and Q defects were defined as pixel values < 20 % of the global maximum. Concordance with CT (reference) was quantified by Cohen’s κ and voxel-wise sensitivity/specificity. Results Seventy-eight patients (age 63 ± 11 y, BMI 24 ± 3 kg m−²) were analysed; CT diagnoses included malignancy with atelectasis (n = 34), pleural mesothelioma (n = 12), pneumonia/consolidation (n = 20) and mixed pathology (n = 12). Case 1 - Pleural mesothelioma, left lower lobe (LLL): 2D-EIT depicted complete V and Q loss in the entire left lung (false extrapolation); 3D-EIT precisely localised preserved Q in LLL despite absent V (V/Q 0), matching CT. Case 2 - Right lung tumour with middle-lobe collapse: 2D-EIT reported global right-sided V/Q absence; 3D-EIT revealed intact lateral-zone Q, enabling differentiation between atelectatic (zero V/Q) and merely compressed (low V, preserved Q) parenchyma. Case 3 - Right upper-lobe (RUL) mass: 2D-EIT showed right-sided V/Q loss; 3D-EIT confined the defect to RUL, consistent with CT. Pooled analysis Sensitivity for focal V-defect detection: 3D-EIT 0.92 (95 % CI 0.86-0.96) vs 2D-EIT 0.73 (0.64-0.81), P < 0.001.Sensitivity for Q-defect: 0.88 vs 0.70, P = 0.002.Specificity remained > 0.95 for both modalities. κ agreement with CT anatomical segment: 3D-EIT 0.81 (substantial) vs 2D-EIT 0.57 (moderate). Conclusions Compared with conventional 2D-EIT, 3D-EIT significantly improves the topographic accuracy of bedside V/Q mapping by capturing cranio-caudal heterogeneity missed by single-plane recordings. The enhanced spatial resolution may facilitate earlier recognition of region-specific pathology and guide targeted interventions in acute and chronic pulmonary diseases.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: