PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 20, 2026Microbiology Spectrum0 citationsOpen Access

Comparative performance of L1- and E6/E7-targeted HPV genotyping assays based on a unified MeltArray platform

View Full Paper
YLYing LiuHQHuihui QuFZFeng Zhang

Key Points

  • The aim is to compare the performance of HPV genotyping assays targeting L1 and E6/E7 genes for detecting cervical cancer.
  • Developed two HPV genotyping assays targeting L1 and E6/E7 using the MeltArray platform.
  • Analyzed 2,477 clinical samples, including liquid-based cytology and formalin-fixed paraffin-embedded specimens.
  • Assessed concordance in HPV detection using Cohen’s kappa statistics.
  • Assays showed 98.8% overall agreement in HPV detection (κ=0.976).
  • High concordance was observed across LBC and FFPE samples, including cases of cervical lesions and cancer.
  • Discordant results were rare, found mainly in types with differing limits of detection.

Abstract

ABSTRACT Human papillomavirus (HPV) molecular testing is central to cervical cancer screening. Commercial assays commonly target either the L1 gene or the E6/E7 oncogenes, yet comparative performance data under standardized conditions remain limited. We developed two HPV genotyping assays targeting L1 and E6/E7 regions, respectively, using the same MeltArray platform to minimize technical variability. Both assays detect 18 high-risk and potential high-risk HPV types. A total of 2,477 clinical samples (2,034 liquid-based cytology LBC and 413 formalin-fixed paraffin-embedded FFPE specimens) were analyzed. Concordance in HPV detection and genotyping was assessed using Cohen’s kappa statistics. The assays showed 98.8% overall agreement in HPV detection (Cohen’s kappa κ = 0.976), with high concordance across LBC and FFPE samples, including high-grade squamous intraepithelial lesion, cervical intraepithelial neoplasia (CIN) 2/CIN 3, and cervical cancer. Discordant genotyping results were rare and concentrated in types with differing limits of detection (e.g., HPV39, HPV52, and HPV66). No substantial detection bias favoring either target gene was observed in cancer cases. When performed under matched analytical conditions, L1 and E6/E7-based assays provide equivalent performance in HPV detection and genotyping. These findings support their interchangeable use in cervical cancer screening, with both targets demonstrating high reliability across the full spectrum of cervical lesions. IMPORTANCE Human papillomavirus (HPV) testing is the principal strategy for cervical cancer screening, with most commercially available assays targeting either the L1 gene or the E6/E7 oncogenes. However, the comparisons of L1 and E6/E7 targets under standardized technical conditions remain limited. In this study, we developed and evaluated two parallel HPV genotyping assays targeting the L1 gene and E6/E7 genes, respectively, using the same MeltArray platform and unified reaction conditions. Analysis of a clinical cohort comprising 2,477 patients demonstrated equivalent performance between L1 and E6/E7 assays in both cervical swab and tissue samples, supporting their interchangeable use in cervical cancer screening.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Liu et al. (2026) studied this question.

synapsesocial.com/papers/6a0d5051f03e14405aa9bf74https://doi.org/10.1128/spectrum.00206-26
Ask AI
Helpful
Bookmark
Share
View Full Paper