Key result
Hybrid CT-echo continuity equation reclassifies 30% of severe AS to moderate without impacting 2-year mortality.
Why the study?
Assumption of a round-shaped LVOT in the continuity equation underestimates true aortic valve area in 2D echocardiography, prompting evaluation of whether CT-measured LVOT area reclassifies AS severity and impacts post-TAVR outcomes.
Does reclassification of aortic stenosis severity using a hybrid continuity equation impact mortality outcomes in patients undergoing TAVR?
Observational
Does reclassification of aortic stenosis severity using a hybrid continuity equation impact mortality outcomes in patients undergoing TAVR?
Routine assessment of hybrid AVAi to reclassify severe aortic stenosis into moderate aortic stenosis does not improve mortality risk stratification for patients undergoing TAVR.
Answers are grounded in this paper and cite their sources.
Hybrid AVAi reclassification does not refine TAVR mortality risk; leaves open its role in AS severity assessment.
BACKGROUND: In the continuity equation, assumption of a round-shaped left ventricular outflow tract (LVOT) leads to underestimation of the true aortic valve area in two-dimensional echocardiography. The current study evaluated whether inclusion of the LVOT area, as measured by computed tomography (CT), reclassifies the degree of aortic stenosis (AS) and assessed the impact on patient outcome after transcatheter aortic valve replacement (TAVR). METHODS AND After inclusion of the CT measured LVOT area into the continuity equation, the hybrid AVAi led to a reclassification of 30% (n = 128) of patients from severe to moderate AS. Multivariate predictors for reclassification were male sex, lower mean aortic gradient, and lower annulus/LVOT ratio (all p < .01). Reclassified patients had significantly higher sST2 at baseline and higher NT-proBNP values at baseline and 6 months follow-up compared to non-reclassified patients. Acute kidney injury was experienced more frequently after TAVR by reclassified patients, but no significant mortality difference occurred during 2 years of follow-up. CONCLUSION: The hybrid AVAi reclassifies a significant portion of low-gradient severe AS patients into moderate AS. Reclassified patients showed increased fibrosis and heart failure markers at baseline compared to non-reclassified patients. But reclassification had no significant impact on mortality up to 2 years after TAVR. Routine assessment of hybrid AVAi seems not to improve further risk stratification of TAVR patients.
No takes yet. Share an insight, caveat, or question.
Weber et al. (2020) conducted an observational in Aortic valve stenosis. Hybrid continuity equation (combining CT and echocardiography data) vs. Classical continuity equation (non-reclassified patients) was evaluated on Mortality. Using a hybrid continuity equation combining CT and echocardiography reclassified 30% (n=128) of severe aortic stenosis patients to moderate AS, but had no significant impact on 2-year mortality.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: